Manual Part No: 930087-01 SNORKEL Gas Convection Oven - 11 –
Manual Rev No: 1
INSTALLATION
Important
Your attention is drawn to the latest, GAS SAFETY (INSTALLATION & USE) REGULATIONS 2000.
This appliance
MUST be installed by a competent person in accordance with these and any other relevant
regulations. Users, too, should be aware of the regulations governing the use of gas appliances,
particularly with respect to the need for regular servicing.
The installation wiring of this appliance
MUST comply with the latest I.E.E. Regulations.
WARNING: THIS APPLIANCE MUST BE ELECTRICALLY EARTHED
Before Installation
Before commencing installation, remove all packaging materials from the appliance. It is suggested that
any protective film adhering to the stainless steel panels should be left on until installation is completed.
BUT THIS MUST BE REMOVED BEFORE COMMISSIONING OR OPERATING THE APPLIANCE.
Check the appliance Data Plate (secured to the top plate of the control panel), to ensure that the
appliance is suitable for the gas supply available.
Ensure that the floor upon which the appliance is to stand is level and capable of adequately supporting
the weight of the appliance.
TO COMPENSATE FOR SOME UNEVENNESS OF THE FLOOR, THE
APPLIANCE
FEET ARE ADJUSTABLE.
THE FLOOR MUST BE FIREPROOF. If it is not, or if any adjacent wall or surface s made of a combustible
material, then the installer must ensure that the requirements of the
LOCAL FIRE REGULATIONS are
observed.
Positioning
Place the appliance in position allowing a minimum gap of 75mm (3”) at the rear and at least 150mm (6”)
between the sides of the appliance and any adjacent walls. The minimum distance between the top of
the appliance and any overshelf or ceiling construction of a combustible material must be 420mm
(16½“).
Adequate ventilation is essential for safe operation of a gas appliance. A supply of fresh air is necessary
for the correct combustion of the gas and there must be a means of exhausting the heat and the
products of combustion from the kitchen. It is recommended that the appliance be sited below a
ventilating hood, one preferably connected to an extractor system incorporating a grease filter.